PRODUCT OVERVIEW
PA Corrugated Conduit
Flexible PA6 conduit designed for reliable cable protection with strong abrasion resistance, weatherability and routing flexibility. It is suitable for automotive harnesses, machinery and engineered wiring, with split, flame-retardant and higher-temperature options available on request.
For selection, verify operating temperature, bundle size, bend radius and installation environment.
Material
PA6 / Nylon 6
Temperature
-40°C to 125°C
Options
UL94 V-0; 150°C grade
Dimensional drawing

Source callouts are retained. CAD or vector originals are needed for a true high-resolution drawing.
Specifications 01
| Size | Inner diameter (mm) | Outer diameter (mm) | Bend radius (mm) | Packing (m/roll) | Notes or connector |
|---|---|---|---|---|---|
| AD7 | 5±0.5 | 7±0.5 | 15 | 500 M | None |
| AD7.5 | 5.5±0.5 | 7.5±0.5 | 15 | 500 M | None |
| AD9 | 6±0.5 | 9±0.5 | 15 | 500 M | None |
| AD10 | 7±0.5 | 10±0.5 | 25 | 500 M | PG7 |
| AD11 | 8±0.5 | 11±0.5 | 25 | 500 M | None |
| AD12 | 9±0.5 | 12±0.5 | 25 | 500 M | None |
| AD13 | 10±0.5 | 13±0.5 | 30 | 500 M | PG9 |
| AD14 | 11±0.5 | 14±0.5 | 30 | 300 M | None |
| AD15.8 | 12±0.5 | 15.8±0.5 | 35 | 200 M | PG11 |
| AD17 | 13±0.5 | 17±0.5 | 35 | 200 M | None |
| AD18.5 | 14.3±0.5 | 18.5±0.5 | 45 | 200 M | PG13.5 |
| AD19 | 15±0.5 | 19±0.5 | 45 | 200 M | None |
| AD20 | 16±0.5 | 20±0.5 | 50 | 200 M | None |
| AD21.2 | 17±0.5 | 21.2±0.5 | 50 | 200 M | PG16 |
| AD22 | 18±0.5 | 22±0.5 | 50 | 200 M | None |
| AD23 | 19±0.5 | 23±0.5 | 50 | 200 M | None |
| AD25 | 20±0.5 | 25±0.5 | 55 | 100 M | PG21 |
| AD28.5 | 23±0.5 | 28.5±0.5 | 60 | 100 M | PG21 |
| AD30 | 25±0.5 | 30±0.5 | 65 | 100 M | None |
| AD32 | 28±0.5 | 32±0.5 | 65 | 50 M | None |
| AD34.5 | 29±0.5 | 34.5±0.5 | 65 | 50 M | PG29 |
| AD42.5 | 36±0.5 | 42.5±0.5 | 80 | 50 M | PG36 |
| AD54.5 | 48±0.5 | 54.5±0.5 | 90 | 25 M | PG48 |
Related products
Specifications come from the source workbook. Images are illustrative; final confirmed specifications govern.